DTS-HD Master Audio Suite™,
User Guide
v 2.5
Confidential - Do NOT Duplicate 42 DTS Document No.: 9301F55800D
17781 v1
When a 6.x channel layout is selected, the second extra channel (i.e. the third fader in each group) will
not be selectable as it is not required for the selected channel layout. Furthermore, when using the 6.x
Discrete channel layout, only the
is valid. If this button is not activated for the 6.x
Discrete channel layout, an error message will be displayed informing the user to activate this button.
Note: When selecting 5.1-channel downmix values for all stream types except DTS-HD Master
Audio, the L, R, C, LFE, Ls and Rs channels must have the same scaling value. In the DTS-HD
Master Audio stream type case, for a 5.1 channel downmix, the scaling value for these channels
can be different.
Note: If the selected channel layout is 5.0, 6.0 or 7.0, the faders under LFE will be deactivated as
this channel is not included in the selected channel layout.
7.4.2 Downmix Saturation Check
The Downmix Saturation Check feature allows a user to check for Saturation (or clipping) in the 5.1
downmix. When the
button is clicked, a File Save browser will display to allow a user
to pick the output directory and file name for their saturation check results log file. Once a directory and
file have been selected by the user, a new job will appear in the Encode Queue with an identical name to
the file name they just chose. When run in the Queue, the Downmix Saturation Check will perform a
‘fake’ encode which will result in a log file containing all saturation warnings (clipping) that were
encountered. No encoded file will be created.
Note: A saturation or clip in the downmix will be recorded anytime 0dBFS is reached for 3 or
more consecutive samples.
Note: Downmix Saturation Check will be disabled when the ‘Folder-Based Encode’ function is
active
Warning: Downmix Saturation Check ONLY checks Saturation in the 5.x downmixes for 7.x
(Master Audio and High Resolution) and 6.x Discrete (Master Audio) channel layouts.
Warning: The Downmix Saturation Check runs a ‘mock encode based on the parameters of the
Encoder at the time the
button is clicked. If ANYTHING is changed that would affect
the Downmix after the Saturation Check is performed, the previously run Saturation Check
should be considered invalid. Each Final Encode log file should always be looked at to ensure
the final Actual’ encoded file does not contain Saturations in the Downmix. (All Saturations
will be located towards to bottom of the related encodes log file)